Non invasive Fat reduction & body contouring Cavitation Ultrasound with Interference frequency
|
Fat Reduction & Body Contouring by
DOUBLE TREATMENTS
|
|
Step 1. Cavitation Ultrasound →
(28khz & 38khz)
|
Step 2. Middle frequency
(Interference)
|
 |
 |
|
(Option)
Abdomen heating pads
|
|
: Melting or dissolution of adiposities
by 28khz or 38khz Cavitation ultrasound
|
: Excretion of dissolved fat by making muscles
exercise with powerful & smooth frequency
|
Effects of Cavitation
Fat reduction & Cellulite decrease
1. Cavitations’ Effect
- Breaking down the fat between adiposities and evacuation into the interstitial.
2. Metabolic Effect
- Increase intra adipocyte pressure by ultrasound vibration à Activation of cell movement
3. Fibrosis Effect
- Effective actions on the fibrosis and for cellulite reduction
Visible body contouring every time of Cavitation Treatment.
| •No anesthesia |
•No Pain |
| •No surgical procedure |
•No risks or scars |
Interference effects
1.Reduction of muscle spasm /Relief of pain
2. Increase in local blood supply
3. Improvement in metabolic efficiency
4. Facilitation of muscle contraction in dysfunctional or unused muscle
5. Increase in muscle strength


ECHOCELL Characteristics
•Maximum adipocyte dissolution & cellulite reduction by 28KHz, 38KHz low frequency ultrasound
•Convenience for specific body parts treatment through stable output controller
•4 patches for interference frequency
•User friendly interface & simple design
•Easy seizable & convenient hand_probe
•Abdomen heating pad for optional treatment

MODE
1. Cross
: Attach each channels seperately
2. Normal
: Attach two channels together for strong interference
Programs
FMA Tapping-rubbing-Acupressure
(Repeated speedily)
FMB T-R-A
FMC R-A
FMD only tapping
FME Acupressure (long)
Final stage : Rubbing &Tapping
SPECIFICATION
- MODEL NAME : ECHOCELL II (CM-5350)
- DIMENSIONS : 440 * 350 * 130 mm
- WEIGHT : 25Kg
- Power input : 100-110V or 200-220V, 50/60Hz
- Consumption power : MAX 200 Watt
- Ultra Sound Output Frequency
: 28KHz ±2KHz(Body), 38KHz ±2KHz(Body, Face)
- Ultra Sound Output power
: MAX 40Watt(28KHz), MAX 60Watt(38KHz Body), MAX 30Watt(38KHz Face)
- Interference high frequency Output Frequency : 4KHz - 3.9KHz
- Interference high frequency Output power : MAX 45mA (LOAD 500Ω)
- User interface : 6.0 Inch Monographic / Touch Button type & Volume controller
Ultrasound Cavitation Technology
|
Stable and controlled Ultrasound
|
: It is a phenomenon that fat cells are dissolved and destroyed by causing cavitation bubbles in cellulite and adipocytes with high energy ultrasound
|
| ↓ ↓ ↓ ↓ ↓ ↓ |
IMPLOSION
Energy emission by powerful bursting
→
|
Effect 1.
Activation of adiposities and
intercellular lipids
|
|
Effect 2.
Breaking or dispersing adipocyte and adipocyte’s cell membranes
|
|

|
What’s CAVITATION ULTRASOUND?
|
Normal Ultrasound
Vibration --> Delivery of the wave types to depend on frequency
Dissolution of Cellulite & body shaping.
|
VS
|
Cavitation Ultrasound
Vibration --> Delivery of low freq. with high energy
Destruction of Adipocytes & Cells membranes
|
|

|
|

|
Unlike normal ultrasound, Cavitation ultrasound disperses fat cell membrane directly, so that fat is emulsified and adipocytes are eliminated.
Process of Cavitation Ultrasound
|
Destruction and Dissolution of Adipocyte
|
 |
 |
|
Before Cavitations
|
5mins later
|
| ↓ ↓ ↓ ↓ ↓ |
 |
 |
| 10mins later |
20mins later |
1. The energy is delivered into the adiposities and body fluid by pressure of over 100kg/㎠ with low frequency ultrasound
2. Activations of adipocyte and interstitial are improved by delivering an Energenic Implosion
3. Finally cell membrane of adipocyte is destroyed.
• It is the most important to generate stable and controlled cavitation bubbles
using low frequency ultrasound.
Interference Frequency
|
Interference frequency is…..
: Historically, it was used for medical purpose which is to decrease muscle cramp pain or relieve muscles by using 4000hz to 4100hz.
It has less skin resistance enough to enter deeply into the skin, so is able to stimulate muscles directly.
* Interference frequency is caused by transformed waveforms when two different middle frequencies are crossed within the human body.
|

|
|

|
Why Interference frequency
 |
-> Two different frequencies more than 4khz, having less resistance, generate newly transformed waveforms which can deliver lots of energy currents, therefore stimulate muscles broadly & deeply.
|
|
1. Comfortable & Smooth feeling, but Strong.
Because of 4 khz, less resistance makes smooth & comfortable feeling to customers. But the transformed waveforms deliver powerful & broad energy within body.
|
|
2. Deep penetration to muscle itself
With less resistance and powerful transformed waveforms, it can go into skin deeply and make muscles itself exercise.
|
|
* Comparing to normal mid frequency,
Interference frequency controls muscles itself because of deep penetration & strong frequency while normal mid/low frequency only controls the nerves on the skin, not muscle itself.
|
Cavitation + Interference

Cavitation + Mid. Freq application
Treatment Sequence
|
① Apply sufficiently transmission gel to treatment area and head of hand piece
↓
|
|
② Gently massage with Cavitation on treatment area
↓
|
|
③ Remove any surplus after 20-30min massage
↓
|
|
④ Attach the pads to treatment area depending on body parts
↓
|
|
⑤ To finish, perform the DETOX massage
|
For Product inquiry, please click HERE.